Post

ThermaVolt, Part 2: The Panel That Stops Discarding Inconvenient Radiation

The summer of 2026 handed the energy sector an awkward lesson. While Europe broke temperature records, solar farms ran at peak output and lost 0.3–0.5% of power per degree above 25 °C. At 55 °C module…

The summer of 2026 handed the energy sector an awkward lesson. While Europe broke temperature records, solar farms ran at peak output and lost 0.3–0.5% of power per degree above 25 °C. At 55 °C module temperature that is roughly 10% of nameplate capacity, evaporating precisely when the sun was strongest. The physics is almost mocking: the brighter it shines, the worse the receiver performs.

We covered ThermaVolt in Part 1. This is Part 2 — on what happens to the energy an ordinary panel throws away.

Silicon Looks Through a Narrow Slit

A silicon panel works on an unforgiving principle. Silicon’s band gap is about 1.12 eV, roughly 1100 nm. A photon with less energy passes straight through; one with more yields exactly one electron, and the surplus goes into the lattice as heat.

Hence the Shockley–Queisser limit: 33.7% for a single-junction cell. Commercial modules deliver 20–23%. The rest is loss, most of it heat, which then strikes output again through the temperature coefficient.

Now the spectrum. Roughly 43% of solar energy reaching the surface is visible, 52% infrared, 5% ultraviolet. Silicon works with the visible and near infrared; the mid and far infrared it does not see, and at night it sees nothing.

Meanwhile the Earth radiates around the clock. Surfaces heated through the day emit in the far infrared. That flux is always there. For silicon it does not exist.

There is an additional irony. A silicon module absorbs almost the entire spectrum — it is dark. It converts only a narrow band into current and turns the rest into heat that works against it. The industry answers with heat sinks and ventilated gaps, treating heat as waste. But this is energy already inside the system.

A Different Logic: Absorb Everything Instead of Filtering

The ThermaVolt panel is built on GLMA, a unique graphene-like material produced by ARBOK’s own technology.

An ordinary panel selects convenient photons and accepts the loss of the rest. GLMA does not select — it captures any incident flux.

The reason is structural. A developed porous morphology makes light reflect repeatedly inside the pores until absorbed almost completely. Optically the material is close to a black body: 95–99% absorption in the visible and near infrared, very high in the mid range.

Broadband behaviour is confirmed outside optics too: in another application the same material delivers over 60 dB of absorption from 30 kHz to 800 GHz, orders of magnitude wider than the solar spectrum. Add stability to 1500 °C.

Here Kirchhoff’s law enters — the law classical photovoltaics treats as a problem. A good absorber is always a good emitter. Heated GLMA re-emits in the infrared. For a silicon panel that would be a disaster. For ThermaVolt it is the working mechanism.

Bifacial Architecture: Sun Above, Earth Below

The panel is bifacial, and each face draws on a different source.

The upper face receives direct and diffuse solar radiation: visible light, near and part of the mid infrared. Everything silicon cannot see enters the balance.

The lower face looks at the ground. By day it collects reflected and thermal radiation; at night it becomes the primary source, since the infrared flux from the cooling but still warm earth and atmosphere does not disappear after sunset. A roof, a wall or another heated surface beneath the panel is an additional option, contributing where it exists.

Night operation includes a second mechanism. A clear sky has an effective radiative temperature of about 230 K, the ground stays near 285 K, and the panel sits inside that difference: the lower side couples to the warm reservoir, the upper radiates into the cold one, and part of the gradient is drawn from the ground-to-sky flow. This is an addition to the main channel, not a replacement.

The panel does not switch off when solar radiation becomes insufficient — and that is only 6–7 hours of work per day, the rest of the time a silicon module sits idle. ThermaVolt moves to terrestrial thermal radiation and works around the clock.

The consequence matters more than the fact. Round-the-clock operation does not change efficiency — that is output over input, independent of duration. What changes is the capacity factor and the annual yield per square metre, the quantities people pay for.

This runs into the weak point of autonomous operation for classical panels — storage. Outside solar hours a household consumes about 70% of its daily energy, most of it in the evening peak. Silicon closes that gap the only way it can: with a battery, charged during the same 6–7 hours the panel works.

ThermaVolt changes this. Generation runs 24 hours a day, including the hours when the load sits — evening peak and night — albeit at lower power than by day. Whether storage is needed at all depends on the consumption profile. Where it remains, its role changes: from the foundation of autonomy, obliged to carry the whole dark period, to a smoothing buffer. That is different capacity and different money. A buffer is sized on two to three hours of average load rather than fourteen dark hours: roughly a fifth to a third of the capacity, 2.5–4.5 kWh instead of 13.5, or some 2,000–4,000 dollars instead of 12,000. An averaged figure, of course — specifics depend on the household.

The price of the question. A domestic 13.5 kWh battery runs to about 12,000 dollars at 850–950 per installed kilowatt-hour, while 8 kW of modules cost around 2,200. The battery is five times dearer than the modules, and its service life is 10–12 years against 25–30 for the panels. Over the lifetime of the installation it is bought two or three times, and storage in total costs more than the entire solar system.

Add to this that the panel is considerably lighter than a silicon one and requires no mandatory southern orientation.

A Second Chance for the Photon

Not all absorbed energy converts immediately into electricity. Part goes into heating, and heated GLMA emits in the infrared. In an ordinary panel that emission escapes and is lost. In a GLMA structure part of the re-emitted flux is absorbed again — by neighbouring elements or by the same surface.

ThermaVolt does not create energy from nothing; it generates it from the losses of the classical approach. It matters which losses. The material absorbs 95–99% immediately, so chasing the remaining percent is pointless. Recapture is needed for something else. A heated absorber radiates on its own, losing energy in proportion to the fourth power of temperature. That is the flux that must be returned to the system. It governs the balance, not the residue of unabsorbed light.

Hence the central point of the design. Kirchhoff’s law cuts both ways: a body absorbing 95–99% broadband emits just as broadly. “Absorb everything” and “lose nothing” are not directly compatible. The resolution is spectral and angular selectivity: high absorption where energy arrives, low emission where it leaks. That is the engineering work itself.

Where the Current Comes From

Absorption and re-emission alone yield only heat. Electricity requires a converter. Three schemes are possible.

1. Thermoelectric channel (Seebeck effect). A temperature difference is established between the hot GLMA side and a cold radiator. The steeper the gradient, the higher the voltage. Simple, no moving parts.

2. Thermophotovoltaic channel (TPV). GLMA heats and emits in the infrared, and photocells matched to that band convert the radiation into current. The emitter shapes the spectrum itself, to suit the receiver rather than the other way round.

3. Hybrid scheme. By day part of the energy travels through ordinary low-bandgap photocells, heat through thermoelectrics. At night only the thermal loop operates.

In all three the advantage is the same: GLMA does not require the radiation to be correct in the first place. It accepts a broad spectrum and brings it to workable form.

Comparison Without Illusions

Silicon panel: captures mainly visible and near infrared; loses almost all mid and far infrared; does not work at night; loses 0.3–0.5% of power per degree; rigid, heavy, requires orientation.

GLMA panel: captures a far broader spectrum; has a second chance through re-emission and reabsorption; works bifacially and around the clock, though at lower power at night; lighter and potentially flexible; far less sensitive to the precise spectral composition of the radiation.

In Part 1 we cited a reference figure of around 80%. This is not light-to-electricity conversion efficiency, where the ceiling is set by Shockley–Queisser. It is an energy utilisation coefficient: the share of incident flux leaving the system as electricity or usable heat rather than rejected.

The figure applies to space conditions, which is what the panel was developed for: full spectrum without atmospheric absorption, cold side radiating into a 3 K background. On Earth the value will be lower.

The distinction is fundamental. Not a perpetual motion machine, but the use of energy ordinary panels ignore and cannot exploit.

What Comes Next

Night flux is weaker than daytime, and re-emission carries losses: the cycle cannot be closed completely, that is the second law. So the principal engineering work lies not in absorption — that we can do — but in holding the gradient and converting heat to electricity efficiently.

ThermaVolt is at the final stage of R&D, the operating principle confirmed. Specific figures will be published after prototype measurements.

Where This Makes the Most Sense

Roofs and façades — the main terrestrial scenario. Bifacial operation, a night contribution, insensitivity to orientation, and above all generation that lands in the evening peak with its expensive tariff.

Off-grid installations — communications, monitoring, field infrastructure, where replacing batteries means sending a crew.

Mobile and flexible surfaces — wherever the weight and rigidity of a silicon module are unacceptable.

The technology came out of a space programme, and that is where its margin in spectrum and gradient comes from. But the problem it solves stands on the ground.

The Point

The idea behind ThermaVolt is not to invent a new law of physics. The laws here are old: Kirchhoff, Planck, Seebeck, the second law.

The idea is to stop discarding most incident radiation merely because it is the wrong spectrum, or because classical methods cannot capture it. GLMA accepts nearly everything, heats, re-emits in the infrared and lets part of that energy be used twice.

The bifacial design allows work with both the sun and the earth.

Not magic, but a fuller use of what is already there — and in that sense the approach does differ from classical photovoltaics.

Silicon asks the photon for its papers. GLMA lets everyone in.


Also published on: LinkedIn — Michael Vischmidt · Facebook — ARBOK Institute