Post

The Graphene Membrane for RO

PREVIEW 💧 An ordinary reverse-osmosis membrane is simple, and there is nothing in it to break. By definition it is infinitely moody, like a teenager who understands nothing about life yet keeps telling you that something…

PREVIEW

💧 An ordinary reverse-osmosis membrane is simple, and there is nothing in it to break. By definition it is infinitely moody, like a teenager who understands nothing about life yet keeps telling you that something is not to their liking and they will not do it. The slightest thing goes wrong, and without warning it fails and stops doing its main (and only) job: making fresh water from the sea. It needs “greenhouse” conditions: strictly defined water density, purity, acidity and temperature. One step left or right, and it is destroyed or clogged beyond cleaning. Everyone knows this, adapted, and even started calling it the “norm”. It was the same with oil lamps: smeared hands, a smoky room, barely enough light to write to the person you loved. You could improve the oil, the wick or the size of the lamp. The same with reverse osmosis: an outdated design means constant suffering. Innovators have only improved the same polymer membrane. ⚙️ Our institute offers the world a membrane of a different class: a 𝗴𝗿𝗮𝗽𝗵𝗲𝗻𝗲 one, with fundamental advantages over the polymer. 📊 But the main question is what desalination costs the plant, and with polymer membranes that is not only millions for a replacement every 𝟯–𝟱 years, but a pile of other headaches.

===

🌊 How membrane desalination works today

Almost all fresh water from the sea is now made by reverse osmosis. Seawater is pushed at 50–80 atmospheres through a polymer film with pores of about 1 nanometer: a water molecule passes, a salt ion with its hydration shell does not. What comes out is fresh but not drinkable water: it has none of the minerals a person needs. Such distillate, without calcium and magnesium, is aggressive: it leaches minerals from pipes and from food during cooking, so the WHO recommends remineralizing desalinated water before it goes into homes. So first RO pulls all the salts out of the water, and then money is spent to add bought salts back in and stir them. Do you still call this a “modern” technology? Over 22,000 desalination plants operate worldwide with a total capacity of about 135 million m³ a day, and most new ones are exactly these “grandfather-era” membrane plants.

Only 30–40% of the water becomes drinkable. The rest is brine, 2.2 times saltier than the incoming water, and it goes back into the sea. In the Persian Gulf, where the water holds 5.2% salt, that is 11–12%. A jar of pickled cucumbers holds 10% salt, and it kills everything alive in it. Pour such brine on a wound and answer for yourself whether it is toxic. And what is it like for marine life and corals?

The whole RO section (pumps, brine, backup generators) uses 8–10 kWh per cubic meter of seawater. They lie to you about 4.5 kWh/m³ in the passport data. It leaves out taking water from the sea over a long distance and pushing it through tanks of sand and carbon. 4.5 kWh/m³ is only the process of pushing water through the membranes. Then comes the removal of 60–70% of the salt brine that did not pass the membranes, which must still be pushed into the sea 300–2,000 meters out. Does anyone count that?

The membrane itself is a polyamide film on a porous support, rolled into a cartridge. It is a consumable, made by a few manufacturers. Like toner for a copier: someone else’s will not fit. The RO membrane market is about $5 billion a year, $10 billion by 2033, and about $100 billion over 10 years for replacement alone. In Pakistan about 100 small RO plants sit idle: there is no money to buy membranes.

⚙️ Why polymer membranes are bad

Polymer is fine until life touches it. Bacteria settle on the membrane first. A slime layer a fraction of a millimeter thick, and flow drops by 20–40%. Same pumps, less water.

So the biggest part of an RO plant is not the membrane hall but everything in front of it: an intake kilometers from the shore, coagulation, sand and anthracite, carbon, ultraviolet. Half of the plant works so that the consumable survives until its replacement date.

Around a single membrane stands a chemical shop of 16 items: chlorine, coagulants, acids and alkali, antiscalants, biocides, corrosion inhibitors, citric acid and EDTA. Chlorine, the simplest remedy against bacteria, destroys polyamide, so the water is first chlorinated, then dechlorinated: 2 stages and 2 reagents to protect the consumable from what was meant to protect it.

The operating window is set by the customer and the parameters are rigid: a dedicated polyamide film is selected for the water’s temperature, acidity and density. So a membrane for a Persian Gulf plant will not work in Venezuela or Algeria. The salinity ceiling is 70–90 PSU, even for the most expensive membrane. Brine at 11–12% is something RO can barely treat: it is practically beyond the ceiling.

Finally, waste. A spent cartridge is not recycled; it goes to landfill (in fact, storage): about 2 million membranes, over 30,000 tonnes of plastic a year. For burial alone the world pays about $2–5 million a year, and as much again with transport. Everyone stays silent about it, and it is a mystery why the “greens” do. While a membrane works, the polymer slowly degrades, and its micro- and nanoparticles end up in drinking water, ranking third among sources of microplastics. Remember: almost all bottled water, plastic or glass, expensive or cheap, passes through membranes, which means… it contains microplastics. Now live with that. Meanwhile seawater turns stainless steel into holey rubble in just 6 months. The headache of the RO equipment maker is the membranes, high energy use and corrosion. The RO system will never solve this: it is a consequence of its design.

The industry got used to all of this and wrote the consumable into the budget as the norm: a warehouse of spare membranes, with a reserve, goes into the plant design from day one. But a norm that is called a norm only because no other options were ever seen is not yet a law of physics. Between “that is how it is done” and “it cannot be done otherwise” lies the distance of one material.

The whole industry now improves the pump and the energy source: solar fields, floating barges, wave pumps. The energy is becoming green. The consumable remains a consumable.

And yes, the membrane fears a power cut like the devil fears incense: within 40 minutes its pores clog with salt, and the membrane must be taken not to intensive care but to the cemetery (to the delight of membrane makers). That is why RO plants always keep diesel generators on standby. And when a manufacturer slyly writes 4.5 kWh/m³ in the passport, it lies: that figure covers only pushing water through the membranes and excludes pre-treatment, post-treatment and pumping the brine back to sea, sometimes over 2–3 km. And nobody will add the diesel generators at a diesel price of €2.5–3 per liter…

🧪 How TEGAMEM works

We stepped on our own throat: instead of Arbok Cold Evaporation, which uses less than 1 kWh/m³ for all processes, has no membranes at all, no chemicals, no corrosion, no consumables, and above all not a gram of brine: all 100% of the seawater taken for desalination is processed. The output is clean, very tasty drinking water plus dry sea salt, a good commodity that earns so much money that the desalination process pays for itself in 5–7 years, and RO does not.

Nevertheless, we decided to develop an alternative to polymer films and build a new kind of reverse-osmosis desalination membrane. Why? One must look the truth in the eye: 22,000 membrane plants worldwide are a big market, and they will not be replaced soon by a modern technology like Arbok Cold Evaporation: the demand for water only grows.

Our membrane is graphene, made of pressed TEGA, a graphene-like material developed by Arbok. TEGA is an open layered graphene structure with a surface area of 2,400–2,600 m² per gram. It has 6 properties, and each closes one of the polymer’s problems. In 2008, scientists of the ARBOK Strategic Research Institute developed a technology for producing TEGA from natural graphite. How exactly it is made is not a separate topic: the know-how stays ours. Everything else is here.

💧 Hydrophobicity. Water does not wet the pore walls: it passes through them only under pressure, and the salt stays outside. The membrane does not compress and withstands 120–150 bar, so 25–30% brine remains instead of 60–70%.

🦠 Bactericidal surface. The biofilm that starts every fouling cycle does not form on the TEGA surface. No biocides, no scheduled washes.

🧴 Chlorine resistance. It is carbon, there is nothing to oxidize. The water can be chlorinated without dechlorination.

🔥 Temperature. The material is stable up to 3,400 °C. Hot effluent needs no cooling before the membrane. One membrane for the Gulf, the Pacific and the Mediterranean.

⚗️ Chemistry. It does not degrade in acids, in alkalis, in light, or with time. Carbon does not crumble into microplastic.

♻️ Feedstock and end of life. TEGA is made from natural graphite, and its cost is only about $50 per kilogram. A spent membrane does not go to landfill: it is regenerated on site as an Arbok service, or replaced with a new one, and the spent graphite is taken back by Arbok, or can simply be thrown away: it is non-toxic and needs no disposal.

There is also a second, simpler use. TEGA has already been used in another water-treatment technology, the TEGFIL gravity filter. Such a filter is installed ahead of the reverse-osmosis membrane in place of a polymer pre-filter. A plant that wants to change nothing puts TEGFIL at the inlet ahead of its own polymer membrane: it holds back suspended solids and bacteria, and the membrane lives longer without any rebuild of the plant.

The graphene membrane is at readiness level TRL-8 and waits its turn for mass production to be set up. Graphene membranes for household and industrial needs. The material itself already works in water.

📊 The numbers

A desalination plant pays for a warehouse of spare membranes, reagents, scheduled washes and planned replacement: that is 5–10% of annual costs. A large plant has from 8 to 210 blocks at $1 million each, and all of them are consumables. A TEGA membrane turns the consumable into a working asset: 3–7 times longer service life, replacement by condition and not by calendar, regeneration on site.

By applying TEGAMEM the operator stops paying for new polymer elements, for dechlorination and biocides, for washes and their effluents, for shutdowns for replacement, for hauling cartridges to landfill. The share of consumables and chemicals leaves the cost of a cubic meter, and the price of water falls by that share.

In the United States there are about 130 municipal plants with a total capacity of 480 million gallons a day.

Worldwide there are over 22,000 plants, more than half of the capacity in the Middle East and North Africa, where warm water fouls membranes faster. All of them need new membranes that solve ever-growing problems.

What TEGA gives. No biofilm for which biocide is poured. No fast destruction. No microplastic as a by-product. No two chlorine–dechlorination stages. Salt-clogged membranes need not be hauled to landfills and paid for.

The graphene membrane is replaced not by calendar but by its condition, and it can operate 3–7 times longer than polyamide, which means no shutdowns for replacement and for acid washes. A warehouse of spare membranes is no longer needed in the plant design. A spent element is not hauled away but regenerated on site. TEGAMEM does not fear temperature, acids, alkalis, bacteria, chlorine or mechanical cleaning. It is still the same reverse osmosis, but it becomes more “normal”, at least without a mass of requirements for the incoming water, which means the process will be simpler and cheaper.

📈 TEGAMEM efficiency: our calculation

The graphene membrane does not compress and withstands 120–150 bar. This mode needs pumps and vessels rated for 120–150 bar; at the usual 50–80 bar the membrane works like an ordinary one, only it does not foul and does not fear chlorine.

Brine. In ordinary RO, 60–70% of the intake water becomes brine. With the graphene membrane 25–30% remains: at 120 bar the water is squeezed down to brine of 117 g/L salt (30% of intake), at 150 bar to 140 g/L (25%). 2–3 times less water and brine has to be taken in and pumped back to sea: a shorter intake, less energy, sand, carbon and reagents at the inlet, a shorter pipe back to the sea. All of this is savings.

Energy. The theoretical minimum rises by 35–45%, from 0.98 to 1.3–1.4 kWh/m³, while intake and pumping fall 2–3 times. The passport 4.5 kWh/m³ remains the reference: the gain is in consumables, reagents and downtime, not in kilowatt-hours.

Flux and area. We expect 25–30 L/m²·h against 13–17 for polymer. For a plant of 100,000 m³/day that is 139,000–167,000 m² of membrane instead of 278,000 m².

Salt in the water. Rejection of 99% and above refers to the salt, not to the water. Of 100 L of seawater holding 3.5 kg of salt, 70–75 L leave as fresh water (about 25 g of salt, up to 350 mg/L in the glass against a limit of 500), and 25–30 L remain as brine with all the rest of the salt: 3.5 kg in 25–30 L is exactly 117–140 g/L. Brine is water that did not pass through the membrane, not salt that did.

Service life. Polymer on seawater lasts 3–5 years, while a TEGA membrane lasts 3–7 times longer, up to the life of the plant itself. Polyamide dies from chlorine at only 1,000–5,000 ppm·h; chlorine, acids, alkali, bacteria and heat do not harm graphene.

Conclusion: the polymer membrane is the weak spot of every reverse-osmosis plant, not because it is badly made, but because it is polymer. The graphene membrane removes that weak spot: it is not replaced by calendar, it does not fear chlorine and heat, it needs no army of reagents. And the water that must be taken in and pumped, and the brine, become 2–3 times smaller.

The polymer membrane has been taught to survive in water for 50 years. Carbon simply lives in it.


Also published on: LinkedIn — Michael Vischmidt · Facebook — ARBOK Institute