Post

Sulfur’s Third Electron vs. the Graphene Electrolyte: 2 Batteries and 10 Points of Comparison

In September 2026 an American research group published, in one of the leading energy journals, a paper the press immediately called a breakthrough: sulfur’s third electron had been “unlocked”. The lithium-sulfur battery raised its average voltage…

Sulfur's Third Electron vs. the Graphene Electrolyte: 2 Batteries and 10 Points of Comparison

In September 2026 an American research group published, in one of the leading energy journals, a paper the press immediately called a breakthrough: sulfur’s third electron had been “unlocked”. The lithium-sulfur battery raised its average voltage from 2.05 to 2.54 V and delivered 58% more charge per gram of sulfur. A worthy result, and I am not going to belittle it. But the ARBOK Institute has its own lithium battery in development — LiGra-BATTERY, in which the liquid electrolyte is replaced by TEGA, ARBOK’s graphene-like material. I will not argue whose is better. I lay both out across 10 identical points and leave the verdict to you.

Where lithium-sulfur came from, and what has always been its trouble

Sulfur is a by-product of oil refining: the US alone recovers about 7.6 mln t a year, at $46–180 per tonne. The theoretical specific energy of the lithium-sulfur pair is 2,600 Wh/kg, several times that of lithium-ion, and the industry has been storming it for more than 30 years.

The trouble with lithium-sulfur was never that the atom has “too few electrons”. The trouble is that sulfur dissolves: polysulfides leave for the electrolyte, shuttle between the electrodes, carry away active material and corrode the lithium anode. The cathode swells, reactions are sluggish, electrolyte is needed in bulk, and few cycles result. Every commercial attempt has broken against these 4 walls.

The chloride cell changes the cathode; LiGra changes the electrolyte

Lithium-sulfur with chlorine changes the cathode chemistry. A classical cell transfers 2 electrons per sulfur atom and ends discharge at lithium sulfide, Li₂S. The new scheme, via chlorine, engages a third electron: Li₂S is reversibly converted to disulfur dichloride, S₂Cl₂. The electrolyte here is a participant in the reaction — an ionic liquid rich in free chloride, an “ionic mediator” in the authors’ words.

LiGra changes the electrolyte. The lithium electrode stays, the cathode chemistry is untouched. The liquid organic electrolyte is replaced by a non-liquid one based on TEGA — thermally expanded graphite. The material’s numbers: specific surface area 2,400 m²/g against 5–20 m²/g for graphite and 300–800 m²/g for activated carbon; thermal conductivity 100–470 W/(m·K), the upper bound above copper; no oxidation, purity at 30–50 ppm of impurities; stable up to 3,400 °C. The bet is on fast ion transport through the developed surface and slow wear of the cell.

Result: a draw. Different routes, both legitimate.

What has been measured, in kilograms and in dollars

Lithium-sulfur with chlorine: average operating voltage 2.54 V against 2.05 V at 25 °C and 0.2C. Sulfur-specific capacity rose by 58%. Electrode-level specific energy — above 1,700 Wh/kg of sulfur; the stack-level estimate, by the authors, is 477 Wh/kg. The 1,700 is measured on a sulfur electrode; the 477 adds lithium, electrolyte and casing.

LiGra: in laboratory cells, a +10% gain in cell efficiency. Calculated specific energy — above 300 Wh/kg against ~180 Wh/kg for lithium-ion cells.

In kilograms, for a 60 kWh battery: lithium-ion — 333 kg; LiGra — 200 kg; lithium-sulfur with chlorine at the calculated 477 Wh/kg — 126 kg. A rough estimate for the +10%: that is 6 kWh per cycle of a 60 kWh battery, 18,000 kWh over 3,000 cycles. At $0.17/kWh in the US that is about $3,000; at $0.20–0.30/kWh in Europe, $3,600–5,400. Sulfur’s gain in money: a 60 kWh battery holds 35 kg of sulfur at $180/t, and +58% saves 21 kg — about $4 per battery.

Result: by kilograms, sulfur — 126 kg against 200. By money, LiGra: sulfur’s gain is worth $4 per battery, LiGra’s gain is worth $3,000–5,400 over the service life. The metric of this article is money; the point goes to LiGra.

Cycle life is where the money is

Lithium-sulfur with chlorine: more than 100 cycles; a single-layer pouch retained 78% of its capacity after 100 cycles. Carmakers build 1,000–1,500 cycles to 20% capacity loss into their warranties.

LiGra: a service life above 3,000 cycles — 3 times a lithium-ion cell and 30 times what the publication shows.

In money. A 60 kWh battery at $108/kWh is $6,480. Lithium-ion at 1,000 cycles delivers 60,000 kWh for that money and is used up by the end of the car’s 1,500 cycles. LiGra at 3,000 cycles delivers 180,000 kWh, 3 times more, and after the car’s 1,500 cycles still holds half its life — $3,240 of residual value for a second life or resale. Lithium-sulfur at 100 cycles delivers 6,000 kWh; a car would need 15 packs, $97,200. A 1 MWh storage unit at $70/kWh is $70,000 and cycles daily, 3,000 cycles in about 8 years: lithium-ion is replaced 3 times, $210,000; LiGra once — $140,000 saved per megawatt-hour. Lithium-sulfur would need 30 units, $2.1 mln.

Result: LiGra. Score 3,000:100; in money — $140,000 per 1 MWh of storage, $3,240 of residual value per car, and 15 packs for lithium-sulfur.

The electrolyte costs more than the sulfur

Lithium-sulfur with chlorine: an ionic liquid rich in free chloride — a salt that is liquid at room temperature, with no solvent. An expensive and viscous class: $200–400/kg in bulk, $500–800/kg battery-grade. The authors themselves write that the prototype holds more electrolyte than a commercial battery can allow.

LiGra: a non-liquid electrolyte based on TEGA. ARBOK makes the material itself; the public price is $50/kg against $10,000–15,000/kg for industrial-purity graphene-like powders on the market. The electrolyte is non-toxic and recyclable.

In money per kilowatt-hour. In a lithium-ion cell the electrolyte is 10–15% of the mass; we take the same share for both chemistries, a gift to lithium-sulfur with its “more electrolyte than needed”. Lithium-sulfur at 477 Wh/kg: 2.1 kg of cell per 1 kWh, of which 0.2–0.3 kg is ionic liquid — $42–250 per 1 kWh for the electrolyte alone; the upper bound costs more than an entire lithium-ion pack. LiGra at 300 Wh/kg: 3.3 kg per 1 kWh, of which 0.33–0.5 kg is TEGA — $17–25 per 1 kWh.

Result: LiGra. Electrolyte: $17–25 against $42–250 per 1 kWh, a difference of 2 to 10 times.

A cell with nothing to burn

Lithium-sulfur with chlorine: the anode is lithium metal, the medium is liquid, with chlorides. Every ailment of the lithium-metal anode stays in place: dendrites, short circuits, lithium lost with every cycle. The third electron does not cure them; it is about the cathode. The polysulfide shuttle is not killed but replaced by sulfur chlorides in an ionic liquid.

LiGra: the electrode is also lithium; the difference is the medium. There is no liquid in the cell — nothing to leak, nothing to burn. The carbon electrolyte does not oxidize, withstands 3,400 °C, and its thermal conductivity of 100–470 W/(m·K) carries heat away from the electrode instead of storing it. Overheating is reduced by design, not by a cooling system.

In money. The market knows the price of a battery fire: one carmaker’s recall of about 140,000 EVs over battery fires cost $2 bln — about $14,000 per car, 2 times the price of the battery. Liquid on lithium metal keeps that risk line; a cell with nothing to burn removes it.

Result: LiGra. The benefit is a $14,000-per-car risk that does not exist.

Heat sets the bill

Lithium-sulfur with chlorine: every figure was obtained at 25 °C. The viscosity of ionic liquids rises with cold, ion transport slows. A battery in the field lives at −10…+45 °C, and the publication is silent about the edges of that range. For comparison, LiPF₆, the standard salt of lithium-ion electrolytes, decomposes above 60 °C.

LiGra: the upper limit is set by the material, not by a solvent. TEGA is stable up to 3,400 °C and does not oxidize; any battery operating range sits inside that with 2 orders of magnitude to spare.

In money. Heat is where the money is. LiPF₆ decomposes above 60 °C, and the industry rule of thumb is that every +10 °C above 25 °C halves a lithium-ion pack’s life: in a car park at +45 °C the pack lives 4 times shorter — 4 packs instead of 1, $25,920 instead of $6,480. Add the range lost in field tests: 17% at +35 °C, $1,100 of a $6,480 pack, and 39–41% at −7 °C, $2,500–2,650 — the loss of a liquid electrolyte that thickens in frost. LiGra’s electrolyte decomposes neither at 60 °C nor at 600: its limit is 3,400 °C, its conductivity of 100–470 W/(m·K) carries heat away from the electrode, and in frost there is no liquid to thicken.

Result: LiGra. 3,400 °C against the 60 °C at which the liquid salt decomposes; up to $19,440 per car saved in a hot climate.

An existing plant against a plant that does not exist

Lithium-sulfur with chlorine: coin cells and 1 single-layer pouch. Before an automotive module come multilayer pouches, hundreds of cells, thermal management, casing — none of it started. There are no production lines in the world for a lithium-metal anode with an ionic liquid.

LiGra: cylindrical, prismatic and pouch on the existing lithium-ion lines. An existing plant assembles the cell on existing equipment: the electrolyte changes, not the industry.

Result: LiGra. An existing plant against a plant that does not exist.

What is left when the cell dies

Lithium-sulfur with chlorine: a solution of sulfur and chlorides in an ionic liquid that needs its own processing step. For scale: in lithium-ion cells the electrolyte is 10–15% of the mass, 100,000–150,000 t of toxic liquid a year. The new chemistry does not remove that fraction; it changes it. The disposal bill remains: incineration at $40–150/t and 300–1,000 kWh/t, landfilling the residue at a further $150–300/t — and since March 2025 the EU bans exporting battery waste outside the OECD, so the solution is processed where it arises.

LiGra: there is no liquid fraction. The electrolyte is carbon: TEGA is ground and regenerated in a furnace into new material, lithium goes back into circulation. Disposal is not cheaper — there is nothing to dispose of.

In money. Incineration plus landfill is $190–450 per tonne of liquid: $0.2–0.7 mln per 10,000 t of spent cells, $20–70 mln a year worldwide, growing with the EV fleet. For LiGra this line is zero.

Result: LiGra. $20–70 mln a year worldwide against zero.

The only metric a buyer pays for

Volts per gram of sulfur is a metric for a journal. The metric for a buyer is $/kWh of a finished battery after 500 cycles. The reference point: the average lithium-ion pack worldwide in 2025 is $108/kWh, stationary storage $70/kWh, North America about $155/kWh. The lithium-sulfur market itself is $0.85 bln in 2025, heading for $2.5 bln by 2030, against hundreds of billions for lithium-ion. Any new chemistry competes with those figures, not with a laboratory table.

Lithium-sulfur with chlorine: to get under $108/kWh it must pay off an ionic liquid at $200–800/kg, a lithium-metal anode and the processing of the spent solution. “Sulfur is cheap, so the battery is cheap” works until the litre of electrolyte is counted.

LiGra: the same metric. A lithium-ion pack at $108/kWh over 1,000 cycles delivers a kilowatt-hour at $0.108. LiGra at the same pack price and 3,000 cycles — at $0.036. Lithium-sulfur at the 100 cycles shown and the same pack price — $1.08 per kilowatt-hour, 10 times lithium-ion.

Result: LiGra. At equal pack price LiGra beats lithium-ion by 3 times and lithium-sulfur with chlorine by 30 times. Count $/kWh per cycle, not volts.

Who makes the electrolyte

Lithium-sulfur with chlorine: the ionic liquid is bought from chemical majors at $200–800/kg; the battery’s price depends on someone else’s price list.

LiGra: an electrolyte made of TEGA, which ARBOK produces itself from carbon, with no rare-earth elements and no outside supplier. Its price, $50/kg, is its own.

Result: LiGra. Own electrolyte against a purchased one.

Ten criteria, one score

So, point by point:

1. What is changed: cathode against electrolyte. A draw.

2. Measured: sulfur saves $4 per battery; LiGra $3,000–5,400 over the service life. Point to LiGra.

3. Cycles: 100 against 3,000. Point to LiGra, $140,000 per 1 MWh and 3 times the energy per pack.

4. Electrolyte: $42–250 against $17–25 per 1 kWh. Point to LiGra.

5. Safety: liquid on lithium metal against a cell with nothing to burn. Point to LiGra, a $14,000-per-car risk removed.

6. Temperature: 60 °C against 3,400 °C. Point to LiGra, up to $19,440 per car in a hot climate.

7. Format: a coin cell against existing plants. Point to LiGra.

8. After the cell dies: $190–450/t against zero. Point to LiGra, $20–70 mln a year worldwide.

9. Economics: $1.08 against $0.036 per delivered kilowatt-hour. Point to LiGra, a 30-fold difference.

10. Electrolyte: purchased against own. Point to LiGra.

As a result, the score is 9:0 with 1 draw. Both technologies are still at the development stage, and there should never be only one good technology. Still, it pays to keep an eye on those doing similar work: it helps avoid dead ends.

In the first case the electrolyte is a crutch to pull 1 more electron out of sulfur. In the second it is the subject of the development itself. What to look for in a battery is not volts per gram, but a reaction and a material with the most watt-hours per cent.

Half a volt of voltage is worth nothing until the price of a kilowatt-hour after 500 cycles is known. Do the sums yourselves.