Michael Vishmidt¹, Dmitry Ponomarenko¹ ¹ ARBOK Strategic Research Institute, Limassol, Cyprus / New York, USA Preprint. Version 1.0, 25 July 2026. Technology Readiness Level 5. Abstract Direct conversion of acid–base neutralization energy into electricity by means…

Michael Vishmidt¹, Dmitry Ponomarenko¹

¹ ARBOK Strategic Research Institute, Limassol, Cyprus / New York, USA

Preprint. Version 1.0, 25 July 2026. Technology Readiness Level 5.

Abstract

Direct conversion of acid–base neutralization energy into electricity by means of bipolar membranes is a known but industrially unexploited pathway. This paper describes Arbok-Acidion, a containerized flow-through electrochemical system in which the reaction H⁺ + OH⁻ → H₂O is converted to electrical current across bipolar membrane assemblies, and in which the working medium can be fully regenerated by reversing the cell. Three features distinguish the system from previously reported acid–base flow batteries: proprietary bipolar membranes not bound by the lifetime and cost limits of the current commercial generation; an electrode assembly built on a proprietary preparation based on a graphene-bearing material, eliminating both noble metals and toxic redox shuttles; and an internal reagent cycle in which hydrochloric acid and sodium hydroxide are produced from desalination brine rather than purchased as commodities. A single 20-foot module delivers 1.2–1.4 MW of continuous electrical output. Variable cost on internally produced reagents is estimated at $0.035–0.08 per kWh, against $0.59 per kWh of fuel-only cost for a diesel generator of equivalent rating under European mid-2026 conditions. The system additionally accepts external acid and alkaline effluent, in which mode the reagent cost becomes negative because operators are paid gate fees for waste treatment. The paper sets out the thermodynamic basis, the system architecture at a level of detail consistent with the protection of proprietary material, the reagent supply chain, the economic assessment, and the open questions that remain before industrial deployment.

Keywords: bipolar membrane; acid–base flow battery; neutralization energy; desalination brine; bipolar membrane electrodialysis; long-duration energy storage; industrial effluent valorization; graphene-bearing electrode

1. Introduction

Global electricity supply is constrained by three structural limitations. Weather-dependent renewable generation provides no firm capacity and requires storage whose capital cost frequently exceeds that of the generation it supports. Thermal generation consumes fuel that must be purchased and transported continuously and is destroyed irreversibly in the process. Nuclear generation is capital-intensive and slow to deploy, and is not available to sites requiring power on a horizon of months.

At the same time, industry neutralizes very large quantities of acid and alkali every year and dissipates the resulting energy as low-grade heat. The free energy of the neutralization reaction is approximately 79.9 kJ per mole at standard conditions, corresponding to 22.2 Wh per mole of proton transferred. Where acid and alkali already exist as process streams or as legacy impoundments, this energy is a stranded resource. Where they do not, they can be manufactured from salt, in which case the system functions as a store rather than a source.

Acid–base flow batteries based on bipolar membranes have been described in the literature since the mid-2010s and have been demonstrated at single-cell and small-stack scale. Reported limitations centre on three areas: co-ion transport losses across the ion-exchange membranes, mechanical stability of the bipolar membrane catalytic interlayer under reverse-bias operation, and parasitic currents through shared manifolds in stacked configurations. Progress in the field has been constrained less by the underlying physics than by the properties of commercially available membranes and by the cost and toxicity of conventional electrode assemblies.

Arbok-Acidion addresses these constraints from the materials side rather than the process side. The membranes and the electrode material are produced in-house, and the reagents are generated within the operator’s own chain from desalination brine. This paper describes the resulting system.

2. Thermodynamic basis

The core conversion element is a bipolar membrane, comprising a cation-exchange layer and an anion-exchange layer joined by a thin catalytic interlayer. Under reverse bias the interlayer dissociates water; under forward operation, with acid supplied to the cation-exchange face and alkali to the anion-exchange face, protons and hydroxide ions recombine spontaneously within the membrane.

The electromotive force follows directly from the ionic product of water. With ΔG = −RT ln(1/K_w) = −79.9 kJ/mol, the theoretical cell potential is E = −ΔG/F = 0.828 V, and measured open-circuit values for working concentrations fall in the range 0.82–0.86 V per cell. Theoretical energy content is approximately 22 Wh per liter of 1 M acid, with an equal volume of alkali required.

Individual cells are assembled into triplets, each comprising a bipolar membrane, a cation-exchange membrane, an anion-exchange membrane and three flow channels. Salt compartments close the internal ionic circuit; terminal electrodes transfer current to the external circuit. The system is fully flow-through: acid, alkali and salt solution are supplied continuously and the dilute product salt solution is withdrawn.

The working pair is hydrochloric acid and sodium hydroxide. This selection follows from three considerations: complete correspondence with the ions of the salt compartment, the highest ionic mobilities available among the common acid and base species, and the highest power densities reported experimentally among acid–base systems.

3. System architecture

3.1 Module

The generating section is housed in a standard 20-foot container. Pumps, main piping, buffer vessels, heat exchangers, inverters and control systems are located externally or chassis-mounted, so that effectively the entire usable internal volume is occupied by generating elements. This is a departure from conventional electrochemical plant layout, in which balance-of-plant occupies a substantial fraction of the enclosure.

3.2 Stack

Stacks are of plate-and-frame construction with sub-millimeter flow channels. The pitch of the repeating element is on the order of one millimeter, yielding an active-surface packing density of hundreds of square meters per cubic meter of volume and, in aggregate, tens of thousands of square meters of bipolar membrane per container. Exact channel and element dimensions are proprietary.

3.3 Electrode assembly

Electrodes and current collectors are fabricated from a proprietary preparation based on a graphene-bearing material developed in-house. The material combines high specific surface area, adequate electronic conductivity and chemical stability in both strongly acidic and strongly alkaline environments. Electrode overpotential is correspondingly low. The assembly contains no noble metals and no ferro/ferricyanide or comparable redox shuttle, removing both the dominant capital cost and the principal toxicological hazard associated with conventional stack terminations. Composition and method of preparation are not disclosed.

3.4 Sectioning and parasitic currents

Parasitic currents through shared manifolds are a recognized loss mechanism in membrane stacks and have been modelled in the literature as accounting for a 25–35 % reduction in round-trip efficiency in unmitigated configurations. In Arbok-Acidion the stack is not a single extended assembly. It is divided into short independent sections, each with its own current collection and output. The section length is selected such that the potential developed along the manifold remains below the threshold at which appreciable shunt currents are established through the solution. The mitigation is therefore geometric rather than hydraulic: it does not rely on elongated channels or dielectric inserts, which suppress shunts at the cost of pressure drop and pumping power. Section length is proprietary.

3.5 Operating envelope

The operating regime is deliberately conservative. Solutions are warmed to well below 50 °C, which raises conductivity and lowers viscosity without approaching the thermal limit of the membranes. Channel velocities are of the order of a few centimeters per second. Current density is on the order of one hundred amperes per square meter, substantially below the regime in which water accumulation and delamination at the bipolar membrane junction have been reported. Net specific power is in the tens of watts per square meter of bipolar membrane. Aggregate module output is 1.2–1.4 MW of continuous electrical power. Capacity is scaled by module count rather than by module size.

4. Reagent supply

The reagent question — how a megawatt-class installation is supplied with acid and alkali — is resolved within the operator’s own chain.

Seawater contains approximately 35 g/L of dissolved salts, of which 27–28 g/L is sodium chloride. Desalination by reverse osmosis, electrodialysis or distillation yields two streams: fresh water, which is a saleable product in its own right, and concentrated brine, which is conventionally a disposal liability. The brine is directed to bipolar membrane electrodialysis (BMED), in which water is dissociated at the membrane interlayer, sodium ions combine with hydroxide to form sodium hydroxide, and chloride ions combine with protons to form hydrochloric acid. Unlike chlor-alkali electrolysis, BMED produces no chlorine gas and no hydrogen, which materially reduces the hazard classification and the infrastructure requirement of the site.

The dilute salt solution leaving the generator is returned to the front of the cycle. Since the salt source is the ocean, reagent output is limited only by available electrical energy and by stack throughput. Where co-produced acid and alkali are available from adjacent soda ash operations, these may be substituted for or blended with internally produced reagent, in which case the reagent ceases to be a purchased input.

Because the reagents are an internal product rather than a market commodity, the cost basis used in Section 7 is the internal production cost, not the exchange price of merchant hydrochloric acid or sodium hydroxide.

5. Reversibility and the storage function

The stack is reversible. On discharge, acid and alkali neutralize and current is delivered. On charge, water is dissociated at the same bipolar membranes, acid and alkali are re-formed from the salt solution, and energy is stored in the chemical separation of the reagents. Regeneration is intrinsic to the architecture: no physical replacement of the electrolyte is required, only the application of current from an external source. Suitable sources include off-peak tariff electricity, curtailed solar or wind generation, and associated gas. Round-trip efficiency of the full cycle is presently in the range 30–55 % and improves with membrane development.

Two consequences follow, and both distinguish the system from combustion generation and from conventional storage respectively.

First, the working medium is recoverable. Combusted hydrocarbon fuel is not: no quantity of input energy reconstitutes diesel from exhaust gas and water. A comparison restricted to instantaneous conversion efficiency therefore omits the dimension in which the two technologies differ most.

Second, in the charged state the system holds not merely stored energy but two commodity chemicals with an independent market price. The operator may dispatch electricity or ship reagent, and may select between the two on a daily basis according to relative prices. No electrochemical storage system in current use offers this optionality.

6. Operation on external effluent

The system accepts external acid and alkaline streams — dilute, contaminated or mixed. Conductivity falls, ohmic resistance rises, additional overpotentials appear, and pre-treatment and more frequent flushing are required. Module output under such conditions falls to 0.5–0.9 MW.

The economics nonetheless improve. Gate fees for the removal and neutralization of acid and alkaline effluent are typically $58–230 per tonne. Where the operator accepts such a stream, the variable cost of the working medium becomes negative and two revenue lines are established: electricity sales and waste treatment fees.

Stream selection is material. Effluents carrying multivalent cations, heavy metals, suspended solids or high organic loads require pre-treatment — settling, filtration and in some cases selective precipitation — and certain species are known to degrade ion-exchange membranes irreversibly. The applicability of the system to any given stream is therefore a matter of composition rather than of pH alone, and must be established case by case.

7. Economic assessment

The reference comparison is a diesel generator of equivalent rating, this being the most widely deployed autonomous source at the megawatt scale. Conditions: Europe, mid-2026; rated output 1.3 MW; 8,000 operating hours per annum.

A megawatt-class diesel generator at full load consumes 0.23 L per kWh, equivalent to 299 liters per hour, 7,176 per day and 2.39 million per year. At $2.55 per liter this is $763 per hour, $18,330 per day and $6.1 million per year, or $0.59 per kWh on fuel alone, before lubricants, filtration, servicing, depreciation and emissions charges.

For Arbok-Acidion, at internal reagent cost equivalents of $35 per tonne of hydrochloric acid and $81 per tonne of sodium hydroxide on a 100 % basis, and a practical yield of 6–10 kWh per cubic meter of solution pair, the working-medium cost is $0.035–0.08 per kWh. Hourly cost is $46–105 against $763; annual cost is $0.35–0.81 million against $6.1 million. The ratio of variable costs is 7–15.

The electrode material is a capital item. At an electrode service life of 5–8 years with partial regeneration, its contribution amortizes to $0.012–0.029 per kWh.

Capital cost of the module is dominated by membrane area and is therefore a direct function of in-house membrane production cost, which is not disclosed here. This is the single most consequential parameter in the economics of the system and is addressed further in Section 9.

8. Deployment context

Beyond the industrial case, the architecture has a specific applicability to communities located adjacent to acid impoundments, tailings ponds and settling basins. Such communities have historically borne the externalities of the adjacent facility without participating in its value.

Arbok-Acidion admits three operating postures at such a site. Where acid or alkaline streams are present, they are simultaneously neutralized and partially converted to electricity. Where such streams are intermittent or absent, the installation runs on reagents produced from brine. Where output exceeds local demand, the site exports either electricity or commodity acid and alkali.

The relevance of in-house membranes, in-house electrode material and an in-house reagent cycle is greatest precisely in this setting: a system dependent on external supply of specialty membranes or merchant reagent cannot be deployed where such supply chains do not reach.

9. Limitations and open questions

The following are stated explicitly as the matters requiring resolution before industrial deployment, and as the subjects of ongoing work.

Bipolar membrane service life under continuous duty at working concentration and temperature is the governing unknown for both economics and maintenance planning. Published data for commercial membranes are not transferable to the membranes used here, and independent long-duration data are not yet available.

Membrane cost per square meter determines module capital cost and therefore levelized cost of electricity. It is not disclosed in this paper for commercial reasons; it will require third-party verification before external investment decisions can be based on it.

Aggregation of the sectioned stack into a single DC bus, and the conversion efficiency of that aggregation, is an engineering task whose losses must be measured rather than modelled.

Performance on real contaminated streams, as distinct from synthetic surrogates, requires field data. Pre-treatment cost for specific effluent classes is not yet characterized.

Co-ion transport has been identified in the literature as the dominant loss mechanism in acid–base systems, accounting for 39–65 % of total losses in reported configurations. Its magnitude in the present architecture requires independent measurement.

The authors regard the appropriate standard for a claimed advance as measured data rather than assertion, and invite partners, desalination operators, chemical and metallurgical plant operators, and independent reviewers to participate in establishing it.

10. Conclusions

Arbok-Acidion is a reversible, containerized, flow-through electrochemical system that converts the free energy of acid–base neutralization to electricity and regenerates its own working medium by reverse operation of the same stack. A 20-foot module delivers 1.2–1.4 MW of continuous output. Working-medium cost on internally produced reagent is estimated at $0.035–0.08 per kWh against $0.59 per kWh for the fuel component alone of an equivalent diesel generator, a ratio of 7–15. On external acid and alkaline effluent, module output falls to 0.5–0.9 MW while the working-medium cost becomes negative through gate fees of $58–230 per tonne.

The system unifies four functions that are conventionally addressed separately: desalination, generation, long-duration storage and effluent neutralization. Its distinguishing features relative to previously reported acid–base flow batteries are proprietary membranes, a graphene-bearing electrode assembly free of noble metals and redox shuttles, and an internal reagent cycle based on desalination brine. Technology readiness is assessed at TRL 5. The principal open question is bipolar membrane service life and cost, on which the industrial case ultimately rests.

References

1. Pärnamäe, R., Gurreri, L., Post, J., van Egmond, W. J., Culcasi, A., Saakes, M., Cen, J., Goosen, E., Vermaas, D. A., Tedesco, M. The Acid–Base Flow Battery: Sustainable Energy Storage via Reversible Water Dissociation with Bipolar Membranes. Membranes, 2020, 10(12), 409.

2. Zaffora, A., Culcasi, A., Gurreri, L., Cosenza, A., Tamburini, A., Santamaria, M., Micale, G. Energy Harvesting by Waste Acid/Base Neutralization via Bipolar Membrane Reverse Electrodialysis: Stack Experiments. Processes, 2020, 8(1), 99.

3. Culcasi, A., Gurreri, L., Zaffora, A., Cosenza, A., Tamburini, A., Micale, G. On the Modelling of an Acid/Base Flow Battery: An Innovative Electrical Energy Storage Device Based on pH and Salinity Gradients. Applied Energy, 2020, 277, 115576.

4. van Egmond, W. J., Saakes, M., Porada, S., Meuwissen, T., Buisman, C. J. N., Hamelers, H. V. M. The Concentration Gradient Flow Battery as Electricity Storage System: Technology Potential and Energy Dissipation. Journal of Power Sources.

5. Performance of Five Commercial Bipolar Membranes under Forward and Reverse Bias Conditions for Acid–Base Flow Battery Applications. Journal of Membrane Science, 2021.

6. Acid–Base Flow Batteries for Sustainable Energy Storage: Balancing Energy Recovery and Efficiency. ACS Omega, 2025.

Acknowledgments

The authors thank the research group of the ARBOK Strategic Research Institute for the underlying process work, and the reviewers whose challenges to the initial cost model materially improved the economic section of this paper.

Author contributions

M. Vishmidt: conceptualization, system architecture, economic analysis, manuscript preparation. D. Ponomarenko: process chemistry, deployment framework, manuscript review.

Competing interests

The authors are affiliated with ARBOK Strategic Research Institute, which holds proprietary rights in the membranes, electrode material and reagent cycle described.

Data availability

Aggregate performance and economic figures are reported in this paper. Membrane composition, electrode preparation, stack geometry and section length are proprietary and are not disclosed. Requests for supervised technical review may be directed to the corresponding author.


Also published on: LinkedIn — Michael Vischmidt · Facebook — ARBOK Institute