๐ง We all drink water. But we now have competitors. Not the robots yet โ their brains, though, yes. Many states no longer allow data centers on their territory. The centers are rich, and they will outbid people for water.
In a small town in Oregon, an American technology corporation drew 12% of the municipal water supply in 2012. By 2025 it was around 40% โ roughly 550 million gallons a year. The figures surfaced only after a lawsuit forced the release of municipal records.
And that is only the share visible on the meter. Up to 80% of the water a data center consumes is lost at the power stations that generate its electricity โ in the cooling towers of thermal and nuclear units, hundreds of kilometres from the site. That share never appears in the facility’s reporting at all.
US data centers consumed 4.4% of the country’s electricity in 2023 and will reach 6.7โ12% by 2028. Practically all of that energy turns into heat. The heat has to leave. The only question is who pays for it in water.
Hence the price of the vocabulary. “Water-neutral” means the consumption has been financially restored in another basin or at another time โ accounting, not the absence of load on the local source. “Closed-loop” means only that the coolant circulates. How the heat leaves the building determines everything else.
๐ญ Two classical schemes, two dead ends
The reference node on which ARBOK calculates its entire cooling line: a 10 000 mยณ/h loop at 8 000 operating hours a year, 186 MW of heat rejection at a delta of 16 ยฐC.
A wet cooling tower evaporates 3.8% of the circulation on that node โ 380 mยณ/h โ and at a delta of 35โ37 ยฐC already 8.7%, or 870 mยณ/h. That is $4.56 million and $10.44 million a year for water alone. Add the blowdown, which has to be treated or legally disposed of. Add the open basin at 32โ42 ยฐC with aerosol rising up to 300 m and droplet drift of 6โ12 km: Legionnaires’ disease carries 15โ20% mortality in the general population and 28% in hospital settings.
The dry scheme removes evaporation and runs into the physics of air: the industry’s best result is 11โ20 K above dry-bulb temperature, which means 51.4 ยฐC at +40 ยฐC air. The price is structure โ a concrete tower 120โ220 m tall, hundreds of finned columns, 4 500โ6 000 mยฒ of plot for the same 186 MW, and an auxiliary load of 0.7โ0.8% of rejected heat on the best systems and 2.6% on modular dry coolers. Those percentages are exactly the electricity that some river pays for at somebody else’s power station.
โ๏ธ The physics ARBOK starts from
The gap between specific heat capacity and latent heat of vaporisation. Water carries 4.18 kJ per kilogram-kelvin as sensible heat and 2 440โ2 450 kJ per kilogram as latent heat. One tonne of evaporated working fluid removes about 680 kWh. That is enough to cool 584 t of water by 1 ยฐC, 58 t by 10 ยฐC, or 5.8 t by 100 ยฐC.
ARBOK-DryTower rejects heat by evaporating a working fluid under deep vacuum inside sealed horizontal vessels, not by blowing air across finned surfaces. The heat transfer coefficients here are those of boiling and condensation โ one to two orders above single-phase liquid convection and incomparably above the air side. This is not a better air cooler. It is a machine that does not need to move enormous masses of air.
The working fluid โ water or alcohol of ARBOK’s own manufacture, matched to the site’s temperature level by vapour density โ is charged once and cycles between evaporation and condensation without touching the atmosphere. It is not a consumable. Makeup covers leakage. The water balance is zero: no evaporative losses, no blowdown, no droplet drift.
๐ฆ Size, energy, schedule
Size follows from phase-change heat transfer. A containerised module transfers 30 MW at a cold line of 30 ยฐC, 62 MW at 45 ยฐC and 109 MW at 60 ยฐC. The reference 186 MW is covered by six modules on 89 mยฒ of plot โ against 4 500โ6 000 mยฒ for a tower scheme of the same duty. A factor of 50โ67 in land.
The auxiliary load is 0.107% of rejected heat, or 0.72 kWh per tonne of evaporated working fluid. That is a net figure for the whole installation, and it stands beside the complete-system 0.7โ0.8% and 2.6% of the competing schools. A factor of 7โ24. This is where the indirect water footprint closes: electricity not spent on cooling generates no evaporation at the power station. The indirect footprint is cut by subtraction, not by declaration.
The schedule follows from the same place. A classical node is construction: tower, foundations, basin, pumping station, high-rise erection, approvals. A containerised module is a delivery. The equipment arrives assembled, sits on prepared ground with no heavy civil works, and capacity is added by module count. The site gets its cooling at the pace of logistics, not at the pace of a building cycle.
โป๏ธ The water in the loop does not degrade
A closed loop normally runs into medium quality: salts concentrate, scale grows, corrosion starts. In the ARBOK line, treatment happens in the same pass as cooling. The circulating water is freed of salts, oils, radionuclides and dust โ no membranes, no catalysts, no consumable chemistry. Impurities leave as a dry solid residue, the material balance is closed, and there are no liquid tailings.
An entire block of obligations disappears with it: blowdown and its disposal, biocides, laboratory control, basin cleaning, the fight with scale and corrosion. The medium is monitored around the clock with reporting to the control room; on deviation the system alerts the operator or moves the installation into a protective mode up to shutdown. Medium quality stops depending on the human factor.
๐ก Dynamics and sanitation
The classical scheme holds several thousand cubic metres of circulating water and presents that thermal inertia as a virtue. For a data center it is a defect. An AI cluster’s load moves in steps: thousands of accelerators enter and leave the count in seconds, and heat output jumps with them. A two-phase loop starts fast and answers a step immediately โ because what responds is vapour pressure, not a mass of water.
The sanitary side is solved by the same structure. No open basin, no droplet drift, no salt aerosol, no visible plume. The Legionella habitat is removed architecturally rather than suppressed with chemistry. For a facility inside city limits, that retires a whole class of liability along with its testing programme and sampling schedule.
๐๏ธ One solution, not a catalogue
ARBOK delivers one thing: the cold line the site specifies, at zero water consumption. New build or an already charged loop, 50 MW or 2 000 MW, a few dozen square metres or a campus in phases โ the configuration is ARBOK’s engineering problem, not the customer’s. The operator states the required temperature, the thermal duty and the site constraints. ARBOK guarantees the temperature.
That is the commercial difference from everyone else in the segment. The competitor sells a fixed physical limit and leaves the rest to the buyer.
On a working site the conversion runs in stages. First the incoming stream is held at a set cold line, touching neither the condenser, nor the circulating pumps, nor the discharge structure: the site receives water colder than the source provides. Then the loop itself is converted to closed operation โ water is charged once and abstraction from the source disappears entirely. The first step is installed in a single construction season and is reversible; the second closes the question for good.
๐ฐ Economics on the reference node
Wet cooling tower: electricity for pumps and fans $576 000โ672 000 a year, water $4.56 million at a delta of 16 ยฐC and $10.44 million at 35โ37 ยฐC, chemistry, biocides, laboratory, cleaning and repair $160 000โ480 000. Total: $5.296โ5.712 million a year at the low delta and $11.176โ11.592 million at the high one.
Closed vacuum cycle: the water line is zero, electricity $230 000โ384 000 a year, planned service $200 000โ300 000. Total: $430 000โ684 000 a year โ and it does not inflate with delta. The operating difference is $4.6โ10.9 million a year on a single node.
Bought outright, the project pays back in about 7 years โ the standard horizon for industrial cooling assets. But buying is neither the only entry point nor the best one.
๐ฆ BOOM: cooling as a service
ARBOK builds, owns, operates and maintains the installation. The data center operator spends no capital, puts no equipment on the balance sheet, hires no staff for a new system and takes on no technical risk. He pays for the result โ per megawatt of heat rejected and for a guaranteed cold line.
For a data center this changes the nature of the expense. Cooling stops being a capital project with a multi-year approval cycle and becomes an operating line โ predictable, and independent of air temperature, water prices and municipal decisions on abstraction. The water line is zero from the first day of operation.
๐ What changes for a data center
Delta stops being a penalty and becomes a resource. In the wet scheme a larger difference means more evaporation and a larger water bill. In the closed cycle a larger difference means more energy carried as vapour and higher absolute internal recovery. A hot day improves the unit’s relative efficiency instead of destroying it. A heatwave stops being an event for the site.
From this follows a direct engineering recommendation. A data center on direct-to-chip liquid cooling runs a cold line of 45โ60 ยฐC. At that line a containerised module transfers two to three and a half times more heat than at 30 ยฐC, the plot shrinks further still, and water consumption stays at zero at any outdoor temperature. Warm water is not a compromise โ it is the most profitable regime.
And water stops determining geography. The site is no longer tied to river flow, river temperature or a permitted return temperature. The subject of the dispute with the municipality disappears: the town does not hand over 40% of its intake, because there is nothing to take.
๐ฏ The choice
The industry today solves its water problem with reporting. That works right up to the moment a facility appears next door with no consumption at all.
An operator can go on buying water at $1.50 per mยณ and offsets on top of it, paying for blowdown treatment, running biocides and living with aerosol liability. Or he can set down containers and close the water line entirely.
The difference between those two options on one 10 000 mยณ/h node is $4.6โ10.9 million a year. The difference for the town downstream is all of its water.
What sits behind your PUE? If the water footprint of your electricity is not in it, half the problem has been counted.
We at the ARBOK Institute have thought about this and decided to share what we found. And if you have this dilemma โ how to supply your center with water โ ๐ DM me.
Also published on: LinkedIn โ Michael Vischmidt