Post

THERE IS NO COOLING PROBLEM. THERE IS LAZINESS AND CONSERVATISM.

⚡💧 The Danube has fallen to 1,400 m³/s. Romania is blasting the riverbed to redirect water to the plant, just to cool a reactor. Cernavodă has shut down Unit 1. Paks is running at a quarter…

⚡💧 The Danube has fallen to 1,400 m³/s. Romania is blasting the riverbed to redirect water to the plant, just to cool a reactor.

Cernavodă has shut down Unit 1. Paks is running at a quarter of its capacity. The Danube’s normal flow is around 3,000 m³/s.

Now the arithmetic nobody shows you.

🏭 A Cernavodă unit: 2,180 MW thermal, 700 MW electrical. The difference — about 1,500 MW of heat — has to be dumped into the river. From two units: 3,000 MW. The intake is designed for 54 m³/s per unit, 108 m³/s for both.

📊 Do the division: 3,000 MW over 108 m³/s heats the water by roughly 6.6 °C. The discharge limit is 28 °C. So with intake water at 25 °C the plant is already outside the law. Not on power. On temperature.

🚨 The constraint is not 700 MW electrical. The constraint is 1,500 MW thermal per unit.

Nobody will let you rebuild the cooling system of an operating NPP — that is years of approvals. There is no time. These plants were designed when nobody expected temperatures like this.

But who forbids putting coolers at the intake?

❄️ ARBOK-PowerCool. 20-foot containers, vacuum boiling at ambient temperature. That is how you pull latent heat out of the stream. The vapour from cold boiling condenses and delivers a flow at the set lower temperature. The process yields up to 98% controllable heat cogeneration, and that heat becomes a source of extra energy. No chemistry, no freon, no cooling tower, no plume. Such a system lowers the temperature of the incoming flow — in August 2026 it runs at +26…+28 °C — down to an acceptable 22–24 °C. ARBOK-PowerCool takes 1,000 m³ from 50 to 10 °C in 8–10 minutes on 2.5–3 kWh.

Two modes:

🅰️ ONCE-THROUGH MODE — containers at the intake hold the set “cold line”. The plant clears the 28 °C limit without a single change to its design. By the summer of 2027, which is forecast to be hotter still — not in 5–10 years.

🅱️ CLOSED LOOP — water is charged into the plant’s cooling system once. Zero discharge, zero makeup. And then the 108 m³/s from the river are simply not needed. Low water stops being a factor at all.

♻️ Along the way the water is cleaned of salts, oils, radionuclides and dust: 0.5–1 kWh/t, no membranes, no catalysts, impurities removed in dry form, water recovery up to 99.98%. Control — ARBOK-Sonar, 24/7.

🌍 And this is not “about nuclear”. The same unit sits at thermal plants, refineries, metallurgy, chemicals, pulp and paper, data centers, LNG terminals, desalination.

⏳ Cernavodă has approved Units 3 and 4. Paks-2 adds 2 more reactors. Both projects — once-through cooling from the Danube. So how are we going to cool them? Tomorrow’s problem is being built today. 180 kg of explosives in a riverbed is not a solution. It is an admission of helplessness.

👉 Working on cooling for power units, refineries or data centers? DM me — ARBOK is open to joint R&D.


Also published on: LinkedIn — Michael Vischmidt