DRY CLOUD lowers air temperature by atomizing water into an ultra-fine aerosol (~5 µm) under ~6 bar of compressed air.
Energy Production
DRY CLOUD lowers air temperature by atomizing water into an ultra-fine aerosol (~5 µm) under ~6 bar of compressed air.
Technology brief
DRY CLOUD lowers air temperature by atomizing water into an ultra-fine aerosol (~5 µm) under ~6 bar of compressed air.
The challenge
Primary use cases:
• Enclosed spaces — cafés, tents, kiosks, cabins, small rooms (up to ~150 m³)
• Transport — aircraft cabins on the ground, train and bus interiors, reefer/cargo holds
• Semi-enclosed sunlit venues — stadium lower bowl, covered stands, atriums, terraces, covered markets, fan zones
Typical scenarios:
• Rapid spot cooling where conventional AC is impossible or uneconomic
• Comfort zones under direct sun
• Venues without fixed cooling infrastructure
Scale:
• Portable single module (<10 kg) for enclosed volumes
• Stationary multi-module systems with mains water for venue-scale zones
ARBOK solution
DRY CLOUD lowers air temperature by atomizing water into an ultra-fine aerosol (~5 µm) under ~6 bar of compressed air. The droplets evaporate completely within fractions of a second, absorbing heat from the air (latent heat ~2.4 MJ per liter) without leaving visible droplets, wet surfaces, or puddles — hence the name "dry cloud." Unlike a conventional air conditioner, there is no compressor refrigeration cycle and no freon: cooling comes directly from the water phase change, so energy use is a small fraction of a comparable AC. The technology is most effective in dry, hot climates and in enclosed or semi-enclosed sunlit spaces, where it delivers real comfort cooling at very low operating cost.
Water is pressurized (~6 bar) and dispersed through fine nozzles into a ~5 µm aerosol. At this size each droplet fully evaporates in 0.025–0.25 s (d²-law) and settles less than 0.2 mm before vanishing (Stokes' law), so no wetting occurs. Evaporation removes sensible heat from the surrounding air, dropping its temperature along a constant-enthalpy (adiabatic saturation) path. Cooling stops at the wet-bulb temperature, so performance is governed by ambient humidity. Compressed air serves as the atomization and mixing medium; about 99% of the cooling comes from water evaporation, not from air expansion.
Key steps:
Limitations:
• Effective only down to the wet-bulb limit
• Works in dry air (RH < ~20–25%)
• Indoor humidity must be vented periodically
Market and application
Target segments: HoReCa terraces, sports and event venues, transport interiors, outdoor public spaces in hot dry regions.
The global evaporative / spot-cooling and outdoor-comfort market is large and growing with rising heat extremes and the freon phase-out. DRY CLOUD's realistic niche is dry-climate enclosed and semi-enclosed sunlit spaces.
Portable module: low CAPEX, water only, ~0.1–0.2 kWh/h.
Café (150–300 m³): one-shot 0.7–2.2 L; continuous hold 4–10 L/h — a small tank.
Venue sector (~8 000 m³): 30–50 modules, 2–5 m³ water/h — far below the cost of air-conditioning an open bowl.
Payback driven by avoided AC energy and equipment.
Use cases
Primary use cases:
• Enclosed spaces — cafés, tents, kiosks, cabins, small rooms (up to ~150 m³)
• Transport — aircraft cabins on the ground, train and bus interiors, reefer/cargo holds
• Semi-enclosed sunlit venues — stadium lower bowl, covered stands, atriums, terraces, covered markets, fan zones
Typical scenarios:
• Rapid spot cooling where conventional AC is impossible or uneconomic
• Comfort zones under direct sun
• Venues without fixed cooling infrastructure
Scale:
• Portable single module (<10 kg) for enclosed volumes
• Stationary multi-module systems with mains water for venue-scale zones
Portable: fill water, switch on, effect in 1–5 min; vent briefly to manage humidity.
Stationary venue zone: site assessment (geometry, wind rose), emitter placement on the windward/upper edge so cool air flows onto people, water-supply connection.
Operating conditions:
• Best in still air (< 1–2 m/s)
• Dry climate (RH < ~20–25%)
Operation is simple, low-skill, and low-maintenance.
Compatible with venue water supply (mains, technical water, stormwater/drainage reuse), standard electrical supply or batteries/solar, and venue climate control with simple sensor/automation (temperature, humidity, timed cycles).
DRY CLOUD lowers air temperature by atomizing water into an ultra-fine aerosol (~5 µm) under ~6 bar of compressed air. The droplets evaporate completely within fractions of a second, absorbing heat from the air (latent heat ~2.4 MJ per liter) without leaving visible droplets, wet surfaces, or puddles — hence the name "dry cloud." Unlike a conventional air conditioner, there is no compressor refrigeration cycle and no freon: cooling comes directly from the water phase change, so energy use is a small fraction of a comparable AC. The technology is most effective in dry, hot climates and in enclosed or semi-enclosed sunlit spaces, where it delivers real comfort cooling at very low operating cost.
Primary use cases:
• Enclosed spaces — cafés, tents, kiosks, cabins, small rooms (up to ~150 m³)
• Transport — aircraft cabins on the ground, train and bus interiors, reefer/cargo holds
• Semi-enclosed sunlit venues — stadium lower bowl, covered stands, atriums, terraces, covered markets, fan zones
Typical scenarios:
• Rapid spot cooling where conventional AC is impossible or uneconomic
• Comfort zones under direct sun
• Venues without fixed cooling infrastructure
Scale:
• Portable single module (<10 kg) for enclosed volumes
• Stationary multi-module systems with mains water for venue-scale zones
Water is pressurized (~6 bar) and dispersed through fine nozzles into a ~5 µm aerosol. At this size each droplet fully evaporates in 0.025–0.25 s (d²-law) and settles less than 0.2 mm before vanishing (Stokes' law), so no wetting occurs. Evaporation removes sensible heat from the surrounding air, dropping its temperature along a constant-enthalpy (adiabatic saturation) path. Cooling stops at the wet-bulb temperature, so performance is governed by ambient humidity. Compressed air serves as the atomization and mixing medium; about 99% of the cooling comes from water evaporation, not from air expansion.
Key steps:
Limitations:
• Effective only down to the wet-bulb limit
• Works in dry air (RH < ~20–25%)
• Indoor humidity must be vented periodically
|Parameter|Conventional AC|DRY CLOUD|
|---|---|---|
|Cooling mechanism|Freon compression cycle|Water evaporation (latent 2.4 MJ/L)|
|Power (comparable effect)|1–1.2 kW|~0.1–0.2 kW (portable module)|
|Refrigerant / consumables|Freon, filters|Water only|
|ΔT achievable (dry climate, +45 °C)|to set point|15–24 °C (to +24…+28 °C)|
|ΔT in humid climate (RH 40–60%)|unaffected|only 7–12 °C, reduced comfort|
|Water use|none|~2–3 L per ~150 m³ (one-shot); 4–10 L/h to hold a café|
|Emissions / noise|medium|near-zero|
Physics note: the marketed "+45 → +12…+15 °C" lies below the wet-bulb floor; the honest, defensible figure is a 15–24 °C drop in dry climates.
Core components:
• Water reservoir
• Compressed-air source (~6 bar)
• Micro-nozzle dispenser / atomizer
• Control unit (cycle and temperature)
Portable version: <10 kg, battery-powered (~100–200 W), 1–3 h autonomy.
Stationary version: nozzle array along the upper edge of the target zone, mains/tank water supply, optional dew-prevention control.
The system is modular — venue zones scale by adding emitters and modules.
Technical:
• Full evaporation, no wetting or puddles
• Instant effect (1–5 min)
• No moving refrigeration parts
Economic:
• Cooling energy comes "free" from the phase change — power a fraction of AC
• Water is the only consumable
• Minimal CAPEX vs trying to air-condition open venues
Environmental / regulatory:
• No freon (banned/quota-limited in the EU)
• No consumables, water only
• ESG-friendly
Strategic:
• Cools spaces where AC is impossible (open/semi-open under sun)
• Portable and infrastructure-free
• Strong fit for hot dry-climate markets (Gulf dry season, MENA, southern Europe, Central Asia, Australia)
Compatible with venue water supply (mains, technical water, stormwater/drainage reuse), standard electrical supply or batteries/solar, and venue climate control with simple sensor/automation (temperature, humidity, timed cycles).
Portable: fill water, switch on, effect in 1–5 min; vent briefly to manage humidity.
Stationary venue zone: site assessment (geometry, wind rose), emitter placement on the windward/upper edge so cool air flows onto people, water-supply connection.
Operating conditions:
• Best in still air (< 1–2 m/s)
• Dry climate (RH < ~20–25%)
Operation is simple, low-skill, and low-maintenance.
TRL 4 (confirmed by Michael). Validated in lab: adiabatic evaporation principle confirmed, ~5 µm aerosol dispersion validated, latent-heat calculations verified (2.4 MJ/L), prototype modules tested for enclosed/cabin applications. (Legacy document claimed TRL 4–6; adjusted to TRL 4 per Michael — field validation and certification pending.)
TRL scale:
Target segments: HoReCa terraces, sports and event venues, transport interiors, outdoor public spaces in hot dry regions.
The global evaporative / spot-cooling and outdoor-comfort market is large and growing with rising heat extremes and the freon phase-out. DRY CLOUD's realistic niche is dry-climate enclosed and semi-enclosed sunlit spaces.
Portable module: low CAPEX, water only, ~0.1–0.2 kWh/h.
Café (150–300 m³): one-shot 0.7–2.2 L; continuous hold 4–10 L/h — a small tank.
Venue sector (~8 000 m³): 30–50 modules, 2–5 m³ water/h — far below the cost of air-conditioning an open bowl.
Payback driven by avoided AC energy and equipment.
• Climate dependence — effective only in dry air; humid climates underperform
• Marketing-vs-physics gap — "+45 → +15 anywhere" and "2–3 L for a stadium" are not defensible and invite expert pushback
• Open-space deployment needs continuous water (m³/h) and many modules — not a single portable unit
• Indoor humidity management; outdoor wind drift
• Conservative adoption and certification timelines
ARBOK-CoolTower — closed-loop industrial cooling
ARBOK MedZWD — vacuum phase separation
SNOWQUEEN — climate / precipitation engineering
Related technologies
LunaLand is ARBOK's integrated technology platform for lunar base construction and energy supply.
SkyWay is an approach to simultaneous energy generation and atmospheric water recovery based on natural physical principles rather than mechanical or chemical processes.
Lunar development is now a question of how and from what, not whether.

Partnership pathway